Now there is a generic resource that can generate and parse
application/json as well as text/plain. It can be re-used, only the
from_string and to_string routines have to be written and the resource
properly set up. A new resource format is specified, see
GENERIC_RESOURCE in, e.g., examples/osd/pwm-example. This is now used in
all my examples, namely pwm-example, arduino-sketch, wallclock-time.
There was an off by one error for the month in time formatting (in
gmtime and localtime). And the leap-year computation was broken. Both
fixed now, so we get a correct date. For localtime we are still 2 hours
off because daylight saving isn't implemented yet.
Also renamed gmtime to utc.
New discovery: Contiki also uses timer 0. With almost the same interface
as Arduino. So we now completely get rid of wiring.c (only the main
file, the other wiring_xxx stay) and implement Arduino timer, delay, etc
in terms of the corresponding Contiki routines. Verified that now delay
works as expected. The LED in examples/osd/arduino-sketch blinks!
Before this, the arduino_init routine in wiring.c destroyed the timer-0
initialization of contiki, making both, contiki timer implementation
*and* contiki timer implementation fail if the arduino_init routine was
called. Now both work.
Squashed with following bug-fix commit.
We can now directly compile arduino sketches (.pde) files.
Arduino compatible analogWrite works now.
But there is still a long way to go, serial I/O and timer stuff (delay,
millis etc) currently don't work (not tested but I don't expect this to
work).
It can be used in an arduino sketch or in a normal contiki program.
We get a PWM frequency of 490.2 Hz (a period of 2.040 ms), that's
Arduino compatible. If you need different frequencies see native timer
usage in examples/osd/pwm-example
In a contiki program you have to call arduino_pwm_timer_init to
initialize the timer before pwm works. The arduino sketch wrapper
already does this.
For running a sketch, see examples/osd/arduino-sketch
New application and new example.
We use the built-in timer routines and add an offset to get the
wallclock time. The offset can be set by time-changing routines
(currently only settimeofday).
We also maintain an offset for timezone handling but this isn't
currently fully implemented.
Currently, the observe value for a response to a GET observe request is always set to zero. That may cause the subsequent notification to have the same observe value. In fact, that happens every time an observable resource is observed for the first time (since the obs_counter is implicitly initialized to zero).
This patch fixes such a problem by setting the observe option value of responses to obs_counter (and then incrementing it).
type process_data_t. This was an artifact when the choice was
made to use the void * type for the data parameter in processes.
Changed parameter 'void * data' of process_post_synch to
process_data_t for consistency.
Checked all the uses of process_start() in contiki and fixed casts
of the data parameter.
This proposed MACRO simplifies jsontree_array declarations. It takes as arguments the name of the array and its size. ( I've modified the indention as requested )
- Up to now the CTK program handler was necessary to start wget and forward the URL. Now alternatively the webbrowser uses the underlying OS to exec wget.
- Up to now windowed CTK was necessary to display the acknowledge dialog. Now alternatively the webbrowser displays the acknowledge text and buttons right in the webpage area.
- For now the targets 'win32' and 'c64' make use of the new capabilities.