bugfix: if timer expired but was not yet handled due to long running operations (such as radio transmits), warn and reschedule timer handling later
This commit is contained in:
parent
8b01f0e3aa
commit
1776fb0449
|
@ -26,7 +26,7 @@
|
|||
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
||||
* SUCH DAMAGE.
|
||||
*
|
||||
* $Id: ContikiClock.java,v 1.10 2009/06/08 13:07:54 fros4943 Exp $
|
||||
* $Id: ContikiClock.java,v 1.11 2009/06/09 19:12:30 fros4943 Exp $
|
||||
*/
|
||||
|
||||
package se.sics.cooja.contikimote.interfaces;
|
||||
|
@ -137,8 +137,8 @@ public class ContikiClock extends Clock implements ContikiMoteInterface, PolledB
|
|||
|
||||
/* Request tick next wakeup time */
|
||||
int nextExpirationTime = moteMem.getIntValueOf("simNextExpirationTime");
|
||||
if (nextExpirationTime == 0) {
|
||||
logger.warn("Next expiration time is now, delaying one millisecond");
|
||||
if (nextExpirationTime <= 0) {
|
||||
logger.warn("Event timer already expired, but has been delayed: " + nextExpirationTime);
|
||||
mote.scheduleNextWakeup(simulation.getSimulationTime() + Simulation.MILLISECOND);
|
||||
return;
|
||||
}
|
||||
|
|